Sigma Spectrum Iv Pump User Manual

  1. Baxter Sigma Spectrum User Manual
  2. Sigma Spectrum Iv Pump Cost
  3. Sigma Spectrum Iv Pump User Manual Software

SIGMA Spectrum Infusion System Pump Operating Software Version 8.00 Operator’s Manual For Use With MDL Version 8.0 INTRODUCTION AND SAFETY Intended Use The SIGMA Spectrum Infusion Pump with Master Drug Library is intended to be used for the controlled administration of fluids. These may incl ude pharmaceutical drugs, blood, blood products.

One moment please...
Sigma spectrum iv pump user manual pdf
  • Parts
DESCRIPTION

Designed with you and your patients in mind.

The SIGMA Spectrum Infusion System has features that help reduce errors when programming an IV infusion. For example, the SIGMA Spectrum Infusion System automatically defaults to using the drug safety library at the initial start of the system. Small, lightweight and easy-to-use, the SIGMA Spectrum Infusion System also offers wireless connectivity to integrate data into a hospital’s EMR system and facilitate the transfer of data to and from the system for updating drug libraries as well as for continuous quality improvement reports.
Rx Only. For safe and proper use of this device, refer to the complete instructions in the Operator’s Manual.

FORUMSView All (33)
Ask a New Question

2

Replies
-TriumphMED
3 months ago
3 months agoUnder Infusing
When testing the Sigma Spectrum we continually get under infusion. In some cases the accuracy is -10%. When sending the pump in to Manufacturer they claim the pump is only under infusing at -4%. We had this happened to many Sigma Spectrum Pumps. We use certified Flowtrax II system also a certified scale to confirm. We also follow the manufacturers recommendation on test parameters and setup. Anyone else having this issue with these pumps? We do not have any issue testing any other brand of pumps including the older Baxter 6201's.Reply
-Chris S
7 months ago
7 months agoError 320 (Latch Switch Error)
Error 320 can occasionally be caused by dirt/debris on either latch switch. Try cleaning with distilled water and a cotton swab before resigning to send the device in for repair.Reply

0

Replies
-Chris S
a year ago
a year agoNuisance Upstream Occlusion Troubleshooting
Nuisance upstream occlusion alarms are typically caused by deformed sections of IV set tubing or by Micro-bubbles collecting in front of the upstream sensor. Here are some tips for troubleshooting upstream occlusion alarms that can not be reproduced by bench testing:1) Keep tubing channel clean and dry. 2)Use only compatible IV sets. 3) Warm fluids to room temp prior to IV Set priming. 4) Fill IV set drip chambers 1/2 to 3/4 full. 5) Invert IV bags to mix (do not shake). 6) Avoid excessive lengths of tubing above the pump. 7) Check all set connections, vents, and filters. 8) Do not load deformed tubing sections into channel. 9) Do not use sets beyond recommended interval. If a Nuisance Alarm is suspected - Check for micro-bubbles and/or deformed tubing in front of the Upstream Sensor. Load a fresh section of the IV set into the tubing channel if bubbles are present.Reply
DOCUMENTS / MANUALSView All






VIDEOS

Baxter's SIGMA Spectrum Infusi...

Baxter's SIGMA Spectrum Infusion System Receives Best in KLAS A...

Baxter Sigma Spectrum User Manual

Sigma spectrum iv pump user manual 2017Sigma Spectrum...

This video is a step-by-step demonstration on how to operate the Sigma Spectrum infusion pump, fo...

FEATURES

  • Multiple Prevention Systems > Configurable dose error reduction software > Single step titration limit > Check flow at start of infusion > Secondary container infusion check
  • Comprehensive log software to create CQI reports; Rapid, Intuitive Work-flow > Easy to set-up and program safely > Bright, easy to read color display > Use of Baxter's standard IV administration sets > Quick drug find library search
  • Economic Value > Utilizes Baxter's standard IV administration sets to help reduce set up time and waste > Facilitates easy training of staff

SPECIFICATIONS

Flow Rate Range0.5 to 999 ml/h
Infusion Pump TypeGeneral-Purpose
KVO Range0.5 to 50 ml/h
Volume to be Infused0.1 to 9999 ml
Height5.8 in
Length 2.5 in
Weight2.5 lbs
Width4.2 in
NEWSView All
How Do You Know Which Infusion Pump is Best?

Infusion pumps are invasive pieces of medical equipment that work to save lives through preventing dehydration, and also aid in the continual release of medication.

Acquisition Enhances Baxter’s Position as a Global Provider of...

Baxter International Inc. announced today it has exercised its option and completed the purchase of SIGMA International General Medical Apparatus, LLC. by acquiring the remaining 60 percent of the company for $90 million.

BAXTER’S SIGMA SPECTRUM INFUSION SYSTEM RECEIVES BEST IN KLAS AWARD...

Baxter International Inc. announced its SIGMA Spectrum Infusion System has received the 'Best in KLAS' award for the second consecutive time at the 2012 Best in KLAS Awards: Medical Equipment & Infrastructure report.

Sigma Spectrum Iv Pump Cost

FDA AlertsView All
Class 1 Recall: Baxter Healthcare Corporation, Sigma Spectrum...

Recall Class:Class I Date Recall Initiated:February 7, 2014 Products: Sigma Spectrum Infusion Pumps with Master Drug Library Model No. 35700BAX and 35700ABB Affected products were manufactured from July 1, 2005

Expanded Class 1 Recall:SIGMA Spectrum Infusion Pump Model 35700

Sigma Spectrum Iv Pump User Manual Software

Based on additional analyses since the initial recall, SIGMA expanded their recall to include additional affected units manufactured from January 18, 2005 through November 1, 2010, with the exception as noted above. These units may fail suddenly